Littleton Plumbing & Fuel Gas Code Amendments
City or town · Arapahoe / Jefferson / Douglas County · Colorado
- Plumbing code
- 2024 IPC
- Fuel gas code
- 2024 IFGC
- Effective
- Jul 25, 2025
- Adopted by
- Ord. No. 11
- Local amendments
- 21
Littleton doesn't use the model plumbing and gas codes exactly as printed. It adopted the 2024 IPC and 2024 IFGC and then made 21 local changes. Some are paperwork, like permits and fees. Others change what you build in the field, including building sewer depth, gas pressure test, gas piping. If you bid off the model book alone, you can miss them. CodeCheck Colorado lists every one in plain English with the official source.
Topics covered
What is Littleton's building sewer depth requirement?
Littleton: building sewers at least 36 in. below grade, including at the septic tank (IPC 305.4.1).
What is Littleton's gas pressure test requirement?
Sign in to see Littleton's rule
What does Littleton change about gas piping?
Sign in to see Littleton's rule
What are Littleton's local venting rules?
Sign in to see Littleton's rule
Does Littleton change any fixture requirements?
Sign in to see Littleton's rule
What permit and fee rules does Littleton add?
Sign in to see Littleton's rule